16/12/2019 V1.0.3 After discussed, we didn’t use the RDM-UID code to identify the pan reset position of these special 8 pcs aperta, because we considered the future after service if the customers change the display PCB ,then the RDM-UID code also will be change and then the software cannot check it is from which batch fixtures. The new idea: We have added a hidden menu to improve these 8pcs pan reset position “Test->Calibrate->Password”; Password=100, pan reset position is correct; Password=110, Pan reset position is inverse. The mass production fixture default Pan position is correct position, so you only need to adjust these 8pcs Aperta password change to “110”, and then reset these fixture,that’s all. The display temperature default Celsius(please re-loading the data after download the software:Function->DFSE->ON) 26/01/2022 V1.0.4 The improved point: -As the STM IC shortage, we changed the MCU to domestic brand(GD) for mass production. In order to keep the software compatible, we improved the software. (Please rest assured that we ensured all the functions works normal and 100% compatible with the sold products before used this software for mass production) 1U / 2U / 3U / 5U : STM MCU --> GD MCU 20/10/2022 V1.0.5 This is the compatible issue for CPU and software ATTENTION UPDATE EN MODE SLOW V1.0.6 - Pan Tilt move improved at low speed - After 2022.8.23 the led module ids a little different as previous. As a result, the calibration of the LEDs must be modified so that manufactures after this date are compatible. Procedure: With software version 106 it is possible to choose the type of calibration according to the date of manufacture of the projector. 1: Directly in the menu Function>LED CAL> B.2022.8.3 or A.2022.8.3. By pressing enter it is possible to precisely adjust the R,G,B values. 2: In dmx via the control channel: - Value 240-245 during 10s selects the calibration before 2022.8.23 - Value 246-250 during 10s selects the calibration after 2022.8.23 - Once the choice has been made, it is possible to adjust the calibration (in case the result is not satisfactory) using the value 251-255 for 10 seconds > adjust the white with the rgb channels of the console > validate the setting by selecting control 000 for 10s. This setting will apply to the previously selected mode. 3: Return to original values: Select the desired mode 240-245 or 246-250 for 10s > Select the value 099 for 10s and return to 000.